Mezzanines for Phoenix and the ValleyLicensed and insured(928) 232-1752

Phoenix Mezzanine Installation (928) 232-1752 Request a quote

Platforms · Walkways

Warehouse Catwalks and Crossover Bridges in Phoenix

A warehouse catwalk system is a run of raised steel walkways that takes people to shelving, machines, air units or across a conveyor. You order the catwalks and crossover bridges through us, and our crew installs them in Phoenix plants and warehouses.

Grating catwalk with yellow guardrail along a high wall, giving access to overhead air units

What Is a Warehouse Catwalk System?

It is a network of raised walkways, usually steel grating on a light frame, that links work points above the floor. Catwalks run along shelving tiers, past machines that need service, up to air units on a wall, or over a conveyor line. IBC Table 1607.1 gives maintenance and service-access catwalks their own row: 40 psf uniform and a 300 lb concentrated load. Walkways that carry more than service traffic use a heavier row.

Our Phoenix mezzanine installers lay catwalks out along the routes your team already walks.

How Much Load Must a Catwalk Carry in Phoenix?

It depends on the use, and Table 1607.1 gives a different row for each. A maintenance catwalk starts at 40 psf, a general walkway or elevated platform at 60 psf, and a stair at 100 psf. A deck that also holds stock moves to the storage rows. Section 1607.3 sets the floor under all of them: the design load is the most the use will bring, and never less than the table.

Which Table 1607.1 row fits your walkway?IBC 2024 Table 1607.1 as adopted in Phoenix, rows 6, 32, 34 and 37
What the deck is forMinimum live load
Maintenance and service catwalk40 psf; 300 lb at one point
Walkway or elevated platform, not an exitway60 psf
Stair or exit100 psf; 300 lb at one point
Deck that also stores stock125 psf light, 250 psf heavy

Read catwalk, walkway or storage deck for help choosing the row.

What Is an Elevated Industrial Walkway?

It is one long, narrow raised route that takes staff along or across a process line: ovens, tanks, conveyors or a row of machines. It lifts service traffic out of the forklift lanes. Walkways and elevated platforms other than exitways start at 60 psf in Table 1607.1. Any open side more than 30 inches above the floor below needs a guard at least 42 inches high (IBC 1015.2, 1015.3). Where the walkway serves electrical, mechanical or plumbing equipment, guard openings may stop a 21-inch sphere instead of a 4-inch one (1015.4).

The platform side is on our industrial work platforms page.

What Is a Crossover Bridge?

It is a short raised walkway with a stair at each end, so people step over a conveyor, pipe rack or machine line instead of walking around it. Each crossover arrives from us as one unit, stairs and rails included, and our crew sets it in place. Arizona's ADOSH enforces the federal general industry rules in 29 CFR 1910, adopted by state rule R20-5-602. So the stairs follow 1910.25: a pitch of 30 to 50 degrees, risers of 9.5 inches at most, and treads of 9.5 inches or more.

  • Clear width of 22 inches or more between the vertical barriers (1910.25(c)(4)).
  • Stair rails and handrails once a flight reaches 3 treads and 4 risers (1910.28(b)(11)(ii)).
  • A top rail between 39 and 45 inches above the walking surface on open sides, which is 42 inches give or take 3 (1910.29(b)(1)).

See stairs, railings and gates for the full set.

Charcoal crossover bridge with stairs on both sides over a roller conveyor of cartons
A crossover with a stair on each side lets staff step over a carton conveyor.

Which Numbers Apply Where the Building Code and ADOSH Differ?

Both sets apply, so where the two disagree, our drawings satisfy each one. The 2024 IBC, as Phoenix adopted it, governs the building. ADOSH governs the workplace through 29 CFR 1910, adopted as of July 14, 2020, which includes the walking-working surfaces rule in force since January 2017. The building code asks for guards above 30 inches and ADOSH at 4 feet, so a walkway 3 feet up still gets a guard. The table sets the main numbers side by side.

Building code and ADOSH numbers for walkways and stairsIBC 2024 as adopted in Phoenix (1011, 1014, 1015); 29 CFR 1910.25, 1910.28, 1910.29 as adopted by ADOSH
ItemBuilding code (Phoenix)ADOSH (29 CFR 1910)
Edge protection beginsOver 30 in4 ft
Guard or top rail height42 in minimum42 in, plus or minus 3
Guard openings4 in sphere; 21 in at equipment walkways19 in
Stair risers and treads7 in max, 11 in min9.5 in max, 9.5 in min
Stair width44 in, or 36 in under 50 people22 in
Stair headroom80 in6 ft 8 in
Handrail height34 to 38 in30 to 38 in

Read 30 inches or 4 feet for the reasons behind the two triggers.

Which Deck Surface Suits a Catwalk?

Bar grating is the usual choice for a catwalk. It weighs little, lets dust and spills drop through, and lets light and air pass. Solid steel plate is the pick where tools or small parts must not fall to the floor below. Smooth panels work where carts roll. Any sprinkler or alarm change for the walkway needs its own fire permit in Phoenix (IBC 105.1 as amended); the Phoenix permit guide explains the steps.

Compare surfaces on our mezzanine decking page and in the mezzanine options gallery. Our cost guide shows what moves the price.

What Does a Catwalk Project Include?

A catwalk job covers the route and its clearances, the grating or plate deck, guards on each open side, and the stairs or ladders at both ends, with complete crossover units where a line must be crossed. You order it from us, and our own crew puts it up, from the first measurements to the last inspection. We line up the engineer's sealed drawings and the permit filing with the City of Phoenix. A single order and a single crew, with one person to call.

  • Site visit: floor size, clear height, slab and the way stock moves.
  • Layout tested against IBC 505 and the ADOSH rail and stair rules before any steel is bought.
  • Drawings sealed by an Arizona-registered engineer, and the permit filing.
  • Delivery of the columns, beams, deck, stairs, guardrail, gates and any lift.
  • Our crew installs it, then the inspections and the posted load signs.

Sources, read November 2026: Phoenix Building Code 2024, Table 1607.1, via UpCodes · Phoenix Building Code 2024, Chapter 10 means of egress, via UpCodes · Phoenix Building Code 2024, Chapter 2 definitions, via UpCodes · Phoenix Building Code 2024, Chapter 1, via UpCodes · OSHA, Arizona State Plan · Ariz. Admin. Code R20-5-602, via Cornell LII · Federal Register 2016-24557, Walking-Working Surfaces · OSHA 29 CFR 1910.25 · OSHA 29 CFR 1910.28 · OSHA 29 CFR 1910.29

01Questions

Catwalk and Crossover Questions from Phoenix Plants

Does a catwalk in Phoenix need a building permit?

Usually, yes. IBC 105.1 calls for a permit, and Phoenix's 105.2 exempts only interior platforms 30 inches or less above adjacent grade that are not over a story below and not part of an accessible route. Most catwalks sit far higher. An exempt platform must still meet the code.

Source: IBC 105.1, 105.2 as amended by Phoenix

What is the minimum catwalk live load in Phoenix?

A maintenance and service catwalk needs 40 psf across the deck and 300 lb at a single point, from IBC Table 1607.1. A walkway or elevated platform that is not an exitway starts at 60 psf, and a walkway that holds stock moves to the storage rows.

Source: IBC Table 1607.1, 1607.3

Do Phoenix catwalk guards follow the building code or ADOSH?

Both. The building code wants a guard on open sides more than 30 inches up, at least 42 inches high. ADOSH, through 29 CFR 1910, wants a guardrail from 4 feet up, with its top rail 39 to 45 inches above the walkway. Where they differ, our drawings meet both.

Source: IBC 1015.2, 1015.3; 29 CFR 1910.28(b)(1), 1910.29(b)(1)

02Request for quote

Build Your Quote

Give us the room, the height and the load you have in mind. A Valley installer answers with questions or a written price.

  1. 1You send the floor size, the clear height and the use.
  2. 2We test the plan against IBC 505 and the ADOSH rules.
  3. 3You receive a written quote that lists each step.

Prefer to talk? (928) 232-1752

Free-standing white steel mezzanine with yellow guardrail on four sides and one stair, seen from above

Build Up Inside Your Phoenix Building

  • Rated for what you store.
  • Drawn to the 2024 Phoenix code.
  • Installed around your schedule.
CallRequest a quote