Stair guide · IBC 1011 and 1910.25
Building Code Stairs or Workplace Stairs? Risers, Treads and Widths Compared for Mezzanines
A mezzanine stair in Phoenix answers to two rule books. The building code sets 7-inch risers, 11-inch treads and a 36- or 44-inch width. The federal rules ADOSH applies allow 9.5-inch risers and treads and a 22-inch width. Where the two differ, the stair is drawn to the stricter figure.

Which Stair Rules Apply to a Mezzanine in Phoenix?
Both the building code and the federal workplace rules. Phoenix enforces the 2024 IBC through its own building code, and its amendment sheets leave the stair, handrail and guard sections, 1011, 1014 and 1015, as written. ADOSH applies 29 CFR 1910.25 and 1910.29 through Arizona rule R20-5-602. Plan review checks the first set; ADOSH enforces the second at work.
The figures below compare them line by line. For the stairs, rails and gates we supply, see our page on mezzanine stairs and railings in Phoenix.
How Do the Building Code and ADOSH Stair Figures Compare?
The building code is tighter on almost every line. Its risers are shorter, its treads deeper and its stairs wider. The headroom figure comes out the same in both, and the handrail bands overlap from 34 to 38 inches. The table puts the two side by side, with the section behind each figure, so you can see which number drives the design.
| Item | Building code (IBC 2024) | ADOSH (29 CFR 1910) |
|---|---|---|
| Riser height | 7 in max, 4 in min (1011.5.2) | 9.5 in max (1910.25(c)(2)) |
| Tread depth | 11 in min (1011.5.2) | 9.5 in min (1910.25(c)(3)) |
| Stair width | 44 in; 36 in for fewer than 50 occupants (1011.2) | 22 in between barriers (1910.25(c)(4)) |
| Headroom | 80 in above the nosing line (1011.3) | 6 ft 8 in above each tread's front edge (1910.25(b)(2)) |
| Handrail height | 34 to 38 in (1014.2) | 30 to 38 in (1910.29(f)(1)(i)) |
Where the two differ, the drawing carries the stricter number, so a single stair satisfies both.
Can a Mezzanine Stair Use 9.5-Inch Risers?
Not on a stair drawn to the building code. IBC 1011.5.2 says "Stair riser heights shall be 7 inches (178 mm) maximum and 4 inches (102 mm) minimum," with treads of 11 inches or more. The federal 9.5-inch figures are a ceiling for the workplace rule, not a design target. So a stair to a permitted mezzanine is laid out with risers of 7 inches or less.
Deck height then sets the size of the stair. A deck 10 feet above the floor needs at least 18 risers of 7 inches or less. With 17 treads at 11 inches each, that flight runs about 15 and a half feet across the floor, before any landing.
How Wide Must a Mezzanine Stair Be?
At least 44 inches under the building code, or 36 inches when the stair serves fewer than 50 people. The federal rule sets a 22-inch minimum between vertical barriers. The occupant load comes from IBC Table 1004.5, which counts floor area per person by use: 500 gross square feet for warehouses, 300 for storage, stock and shipping areas, and 150 for business areas.
So a 6,000 sq ft storage deck at 300 square feet a head works out to 20 people, under 50. A 9,000 sq ft office deck at 150 a head comes to 60, which calls for the full 44 inches. Plan review sets the final occupant load.
How Much Headroom Does the Stair Need?
80 inches under both rule books, measured from slightly different points. IBC 1011.3 measures "vertically from a line connecting the nosings." The federal rule, 1910.25(b)(2), asks for 6 feet 8 inches of clearance above any tread, measured from the front edge of that tread. Six feet eight is 80 inches, so one clearance satisfies both.
Headroom is easy to lose under a deck. Beams, light fixtures and sprinkler pipes all hang into the space above a stair that tucks below part of the mezzanine. We check the stair path against the steel and the services on the drawings.
What Handrail and Stair Rail Heights Work for Both?
Handrails at 34 to 38 inches, with a stair rail of 42 inches or more on any open side. IBC 1014.2 sets handrails between 34 and 38 inches; the federal band runs from 30 to 38 inches, so 34 to 38 meets both. Under 1910.29(f)(1)(ii)(B), any stair rail system put in from January 17, 2017 onward reaches at least 42 inches, measured up from the front edge of the tread.
Group F plants have one building code option. Where exit access stairs serve fewer than three stories and are not open to the public, the top of the guard may double as the handrail at 34 to 38 inches (1015.3 exception). The federal stair rail rule still applies to that same rail, so the drawing has to satisfy both before the option is used.
What Do Landings, Slope and Strength Add?
Three federal checks that sit alongside the building code figures. Under 1910.25(b)(4), landings are "at least the width of the stair and at least 30 inches (76 cm) in depth." Standard stairs are set at an angle between 30 and 50 degrees. Each stair must carry five times its normal live load, and never less than 1,000 pounds at any one point. Table 1607.1 adds the building code's own stair load: 100 psf, with a 300-pound concentrated load.
Our crew installs the stair with its rails and gates as part of the same order. Read how our Phoenix mezzanine installers run a full job, from layout to inspection.

Mezzanine Stair Questions, Answered
Can a mezzanine stair in Phoenix have 9.5-inch risers?
Not on a stair drawn to the building code. IBC 1011.5.2 limits risers to 7 inches and sets 11-inch minimum treads. The 9.5-inch figures are the federal limits ADOSH applies under 29 CFR 1910.25, and the drawing follows the tighter rule.
Source: IBC 1011.5.2; 29 CFR 1910.25(c)
How wide does a mezzanine stair need to be in Phoenix?
44 inches under IBC 1011.2, or 36 inches when the stair serves an occupant load under 50. The federal minimum is 22 inches, so the building code figure decides.
Source: IBC 1011.2; 29 CFR 1910.25(c)(4)
Is the stair headroom rule different under ADOSH in Phoenix?
No. Both come to 80 inches. IBC 1011.3 measures from a line connecting the nosings, and 29 CFR 1910.25(b)(2) asks for 6 feet 8 inches of clearance above each tread, measured from its front edge.
Source: IBC 1011.3; 29 CFR 1910.25(b)(2)
What handrail height satisfies both codes in Phoenix?
34 to 38 inches. IBC 1014.2 sets 34 to 38 inches, and 29 CFR 1910.29(f)(1)(i) allows 30 to 38 inches, so the building code band fits inside the federal one.
Source: IBC 1014.2; 29 CFR 1910.29(f)(1)(i)
Sources, read November 2026: Phoenix Building Code 2024, Chapter 10 means of egress, via UpCodes · OSHA 29 CFR 1910.25 · OSHA 29 CFR 1910.29 · Phoenix Building Code 2024, Table 1607.1, via UpCodes · City of Phoenix, 2024 IBC amendment sheets · Ariz. Admin. Code R20-5-602, via Cornell LII