Accessibility guide · IBC 1104.4
Does a Mezzanine in Phoenix Need an Accessible Route? IBC 1104.4 and Its Exceptions
The building code Phoenix enforces says an accessible route must connect each accessible mezzanine in a multilevel building, and Phoenix rewrote the rule's title to make that plain. The code then lists exceptions. This guide quotes the rule and each exception as written; plan review decides which, if any, fits a given building.

What Does IBC 1104.4 Say About Mezzanines?
It calls for an accessible route to each accessible mezzanine. As Phoenix adopted it, Section 1104.4 reads: "At least one accessible route shall connect each accessible story, mezzanine and occupiable roofs in multilevel buildings and facilities." The rule sits in Chapter 11, the accessibility chapter of the building code, and plan review reads it alongside Section 505.
So the question for a new deck is not only whether it fits under Section 505, but also whether it needs a route. Our Phoenix permits and code page shows where this sits in the filing, and our page on elevated warehouse offices covers decks with offices on them.
What Did Phoenix Change in Section 1104.4?
The title. Phoenix struck "Multistory" and wrote "Multilevel buildings and facilities." Its amendment sheet explains that the old title "has been interpreted in the past to limit Section 1104.4 to multistory buildings and not multilevel buildings." Read with that note, the rule speaks to buildings with more than one level, not only to buildings with more than one story.
The sentence of the rule already spoke of multilevel buildings and facilities. Phoenix brought the heading into line with it, so the two now say the same thing.
What Is the 3,000-Square-Foot Exception?
It is a size-based exception with a list of places it does not reach. The code text reads: "An accessible route is not required to stories, mezzanines and occupiable roofs that have an aggregate area of not more than 3,000 square feet (278.7 m2) and are located above and below accessible levels." Note the word aggregate: the areas of the levels in question are added together. The same text says the exception does not apply to these:
- Group M multi-tenant facilities with five or more tenant spaces.
- Offices of health care providers.
- Passenger transportation facilities and airports.
- Government buildings.
- Structures with four or more dwelling units.
Whether a deck fits this exception is a plan review call, made from the areas and uses on your drawings.
What If a Level Holds No Accessible Elements?
The code has a separate exception for that. It reads: "Stories, mezzanines or occupiable roofs that do not contain accessible elements or other spaces as determined by Section 1108 or 1109 are not required to be served by an accessible route from an accessible level." Two nearby sections in Chapter 11 shape what a level may hold.
- Employee work areas (1103.2.2): spaces within them need meet only a few listed sections, and must be built so people with disabilities can "approach, enter and exit the work area."
- Equipment spaces (1103.2.9): "Spaces frequented only by service personnel for maintenance, repair or occasional monitoring of equipment are not required to comply with this chapter."
These sections describe how the code is built; they do not settle any one building. Plan review reads them against the uses shown on the deck.
When Does the Small Two-Story Exception Come Up?
Only in a narrow case. The text reads: "Where a two-story building or facility has one story or mezzanine with an occupant load of five or fewer persons that does not contain public use space, that story or mezzanine shall not be required to be connected by an accessible route to the story above or below." Every condition in that sentence has to hold.
Occupant load comes from IBC Table 1004.5, which counts floor area per person by use. That number, and whether any public use space sits on the level, decide whether the sentence fits.

How Does the Code Treat a Raised Equipment Platform?
As a different kind of level from a mezzanine. Chapter 2 defines an equipment platform as "An unoccupied, elevated platform used exclusively for mechanical systems or industrial process equipment." Section 505.3 adds that "Equipment platforms shall not be a part of any mezzanine." And Section 1103.2.9, quoted above, covers spaces that only service personnel visit for maintenance, repair or occasional monitoring.
Whether a raised level counts as an equipment platform or a mezzanine depends on how it is used, and plan review makes that call. A platform that starts to hold storage or work stations no longer matches that definition.
Does an Office on the Deck Change the Answer?
It can, because offices bring people and uses that the exceptions turn on. An office raises the occupant load, at 150 gross square feet per person for business areas in Table 1004.5, and it may include space the public uses. A storage deck that only staff reach raises different questions. Both run through the same rule and the same exceptions, with different facts.
Our guide to adding an office mezzanine to a Valley warehouse covers the loads, exits and occupancy that come with an office level.
Who Decides Whether an Exception Applies?
The City of Phoenix does, through plan review. We do not tell a buyer that a deck is exempt. What we do is put the facts plan review needs on the drawings: the area of each level, its use, its occupant load, whether the public can reach it and what elements it holds. The reviewer applies 1104.4 and its exceptions to those facts.
If a route is required, it becomes part of the design from the start, and the layout changes to suit it. Talk it through with our Phoenix mezzanine installers before the drawings are sealed.
Accessible Route Questions, Answered
Does every mezzanine in Phoenix need an accessible route?
IBC 1104.4 calls for an accessible route to each accessible mezzanine in multilevel buildings, then lists exceptions. Which exception, if any, fits a given deck is decided in Phoenix plan review.
Source: IBC 1104.4 as amended by Phoenix
Why did Phoenix change multistory to multilevel in Section 1104.4?
Its amendment sheet says the old title had been read to limit the rule to multistory buildings and not multilevel buildings. The new title removes that reading.
Source: City of Phoenix, 2024 IBC amendment sheets
Does a staff-only mezzanine in Phoenix still need an accessible route?
The code has rules that bear on it, such as Section 1103.2.2, which says employee work areas must let people with disabilities approach, enter and exit the work area. Plan review weighs those rules against the deck's uses, and we never treat a deck as exempt in advance.
Source: IBC 1103.2.2 and 1104.4
What does the 3,000 sq ft exception say in Phoenix?
The code text says no accessible route is required to stories, mezzanines and occupiable roofs with an aggregate area of 3,000 square feet or less, located above and below accessible levels. It does not apply to the building types the code lists, such as government buildings and health care provider offices.
Source: IBC 1104.4 exception
Sources, read November 2026: Phoenix Building Code 2024, Chapter 11 accessibility, via UpCodes · Phoenix Building Code 2024, Chapter 10 means of egress, via UpCodes · Phoenix Building Code 2024, Section 505, via UpCodes · Phoenix Building Code 2024, Chapter 2 definitions, via UpCodes · City of Phoenix, 2024 IBC amendment sheets