Deer Valley and North Phoenix: Platforms and Mezzanines for Advanced Manufacturing

North Phoenix around Deer Valley Airport is turning into a manufacturing, technology and distribution area. Plants there need equipment platforms, raised control rooms and storage decks, and the building code treats each of those differently.

Raised control room glazed on four sides on charcoal columns, with a stair and walkway above a plant floor

What Is Driving Industrial Growth in Deer Valley?

Industrial land, the airport and new manufacturing. The City of Phoenix says "The Deer Valley Village has considerable commerce and industrial land which will satisfy basic employment needs." The City's airport brochure goes further: "The entire community of Deer Valley is experiencing an economic boom as it evolves into a sought-after commercial, advanced manufacturing, technology and distribution hub." Its map of the airport's neighbours is titled "Northwest Industrial Airpark."

Plants like these need raised steel of several kinds. See industrial work platforms in Phoenix for equipment and work platforms, and observation towers and control rooms for raised, glazed rooms over a plant floor.

How Much New Industrial Space Is Forecast Around the Airport?

The City's 2023 Deer Valley Airport brochure projects "an estimated new demand of 7.4 million sq ft in logistics warehouses, flex industrial, and flex office area by 2028." That is a forecast from the City of Phoenix Aviation Department, not a count of finished buildings. The same brochure places the airport "along the I-17 corridor" and notes a semiconductor fabrication plant being built north of Deer Valley Airport.

Other public figures point the same way. The 2022 economic impact report for the Phoenix airport system counts "705 private sector jobs at the airport, including a major industrial park." At the city's northern edge, the North Gateway Village "strives to offer a high quality regional employment center," in the City's words.

White steel mezzanine with storage cabinets above a row of glass-covered electronics assembly machines
Storage cabinets on a steel deck above a row of glass-covered electronics assembly machines.

When Is a Raised Level an Equipment Platform Instead of a Mezzanine?

When nobody occupies it and it exists only for machinery. The code defines an equipment platform as "An unoccupied, elevated platform used exclusively for mechanical systems or industrial process equipment." That status changes how it is counted. Under IBC 505.3, it is not a portion of the floor below, adds no building area or story, and stays out of the fire area used for sprinkler rules.

It also stands apart from mezzanines. Equipment platforms "shall not be a part of any mezzanine," and the walkways, stairs and ladders that reach them cannot serve as exits from the building. Their own limits follow:

  • Area: all equipment platforms in a room total no more than two-thirds of the room (505.3.1).
  • Shared rooms: a mezzanine plus an equipment platform total no more than two-thirds of the room, and the mezzanine keeps its own cap (505.2.1.1).
  • Sprinklers: above and below the platform where the building must be sprinklered and the referenced standards require it (505.3.2).
  • Guards: where Section 1015.2 requires them (505.3.3).
Charcoal grating platform carrying two stainless mixing vessels, with yellow guardrail and a stair
A grating platform carrying two mixing vessels, with its own stair and guardrail.

What Does an Industrial Work Platform Need?

A load row that matches the work and guards at the edges. When people work on a raised level, rather than only servicing equipment, it no longer fits the unoccupied definition. Table 1607.1 lists walkways and elevated platforms other than exitways at 60 psf. Production on the deck points to the manufacturing rows instead: 125 psf light or 250 psf heavy, with 2,000 lb or 3,000 lb concentrated loads.

Edges follow two sets of numbers. IBC 1015.2 puts guards along open sides more than 30 inches above the floor below. At elevated surfaces for access to equipment, openings may pass up to a 21-inch sphere under 1015.4. ADOSH, which adopts 29 CFR 1910, adds its own top rail height of 42 inches, plus or minus 3. Our drawings meet both sets wherever they differ.

Can a Control Room or Observation Tower Be Glazed on All Sides?

Yes, in industrial facilities. IBC 505.2.3 normally keeps a mezzanine open to the room, but one exception reads: "In industrial facilities, mezzanines used for control equipment are permitted to be glazed on all sides." That is the rule behind an elevated control room or a supervisor observation tower with glass on every wall, looking down over the line.

The other mezzanine rules still apply. The room needs at least 7 feet of clear height above and below its floor construction under 505.2, and plan review applies the Chapter 11 accessible-route rules and decides whether any of their exceptions fits. If the room will hold desks rather than control equipment, the office exceptions apply instead. Our guide to an office mezzanine in a Valley warehouse covers those.

What Should a Plant Send Before Pricing a Platform or Tower?

Enough detail to tell an equipment platform from a work platform or a control mezzanine, since each one follows a different code path. Photos of the area help, and so does a rough sketch with the main dimensions. We confirm the rest on a site visit before any steel is drawn, and the engineer sets the final loads.

  • The equipment the platform carries, with weights and footprints.
  • Who goes up there, how often and for what work.
  • The clear height to the lowest beam, duct or sprinkler pipe.
  • Any vibration, washdown or chemicals near the steel.
  • For a control room or tower: the view it needs and the equipment inside.

Which Rules Apply to Deer Valley Plants?

Phoenix's own, because Deer Valley Village is inside the city. Projects follow the 2024 Phoenix Building Construction Code, which took effect on August 1, 2025, and commercial permits are filed through SHAPE PHX. Structural steel is either built by an approved fabricator or inspected during fabrication under IBC 1704.2.5.

Phoenix runs an approved fabricator program that "Ensures the fabricator shop is inspected and accredited by a 3rd party agency" and, in the city's words, "Saves customers time and money by bypassing required special inspections of fabricated products." Sprinkler and alarm changes go on a separate fire permit. We line up the sealed drawings, the steel and the filing, and our crew installs the platform, tower or deck. Start at our mezzanine installation in Phoenix page.

Deer Valley Platforms and Mezzanines: Common Questions

Do equipment platforms in a Deer Valley plant count as mezzanine area?

No. IBC 505.3 says equipment platforms are not part of any mezzanine. A room that holds both caps the two together at two-thirds of its floor area, and the mezzanine alone keeps its own limit.

Source: IBC 505.2.1.1 and 505.3

Can a control room on a Phoenix plant floor have glass walls all round?

Yes, in industrial facilities. IBC 505.2.3 lets mezzanines used for control equipment be glazed on all sides. The 7-foot clear height rule above and below still applies.

Source: IBC 505.2 and 505.2.3

What live load does a work platform in a North Phoenix plant need?

Walkways and elevated platforms other than exitways start at 60 psf in Table 1607.1. If production happens on the platform, the manufacturing rows apply: 125 psf light or 250 psf heavy. Your engineer sets the final rating.

Source: 2024 IBC Table 1607.1

Is the Deer Valley demand figure a measured count?

No. The 7.4 million sq ft figure is a projection to 2028 in the City of Phoenix Aviation Department's 2023 Deer Valley Airport brochure. Treat it as a forecast of demand, not as space already built.

Source: City of Phoenix Aviation, Deer Valley Airport brochure

Sources, read November 2026: City of Phoenix, Deer Valley Village · City of Phoenix, North Gateway Village · City of Phoenix Aviation, Deer Valley Airport brochure · City of Phoenix Aviation, Economic Impact of the Phoenix Airport System (2022) · City of Phoenix, Building Code (2024 PBCC) · Phoenix Building Code 2024, Section 505, via UpCodes · Phoenix Building Code 2024, Chapter 2 definitions, via UpCodes · Phoenix Building Code 2024, Chapter 10 means of egress, via UpCodes · Phoenix Building Code 2024, Table 1607.1, via UpCodes · Phoenix Building Code 2024, Chapter 11 accessibility, via UpCodes · Phoenix Building Code 2024, Chapter 17 special inspections, via UpCodes · City of Phoenix, Approved fabricator resources · OSHA, Arizona State Plan · Ariz. Admin. Code R20-5-602, via Cornell LII · OSHA 29 CFR 1910.29

Raise a Platform or Control Room in Your Plant

Send the equipment, the people who will use the level and the clear height. We sort out the code path, supply the steel and install it with our own crew.

CallRequest a quote